The DH-485 communication network allows devices on the plant floor to share. information. Via the network, application programs can: • monitor process and device parameters and status, including fault and alarm detection.

Is DH485 the same as RS485?

DH 485 is a protocol, like Modbus and DF-1 are protocols. RS485 is an electrical specification for the physical layer connections. They are not related or compatible.

Is Ethernet a DH485?

5201-DFNT-DH485 This stand-alone DIN-rail mounted protocol gateway provides one Ethernet port and one DH-485 configurable serial port. The ProLinx DH485 protocol driver supports the Master and the Slave modes of the protocol, providing powerful data transfer capability with Rockwell Automation PLCs and HMIs.

What is the maximum distance that a DH 485 network can span from the first node to the last node?

It is generally accepted that RS-485 can be used with data rates up to 10 Mbit/s or, at lower speeds, distances up to 1,200 m (4,000 ft). As a rule of thumb, the speed in bit/s multiplied by the length in metres should not exceed 108.

What is Data Highway Plus?

The Data Highway Plus (DH+) network is a local area network designed to support remote programming and messaging between computers and controllers for factory-floor applications.

What is RS-232 and RS485?

RS485 and RS232 are only the physical protocol of communication (ie interface standard), RS485 is the differential transmission mode, RS232 is the single-ended transmission mode, but the communication program does not have much difference.

What is the dh-485 port used for?

• DH485 – used to interface the module with the DH-485 network. This port is not isolated and cannot directly drive a multi-node DH-485 network. You must use a 1747-AIC link coupler to connect this port to a DH-485 network that includes multiple SLC 500 processors.

What is the dh-485 industrial local area network?

The DH‑485 industrial local area network is designed for factory-floor applications and uses the RS‑485 transmission standard. Supports connection of up to 32 devices, including SLC™ 500 and MicroLogix™ 1000 controllers, graphic terminals, and personal computers

How do I communicate with a dh-485 slave?

Slave-to-slave Communication The interface module lets communication from a DH-485 network device to a single DF1 slave device, regardless of which mode of half-duplex addressing is selected (local or remote). To achieve this, the interface module’s Master Station Address must be configured as that DF1 slave address.

What is the pass through rate of dh-485?

Pass Through Disabled Enabled, Disabled Determines whether diagnostic commands are executed by the module (Disabled) or passed through to the host (Enabled). Communication Rate 19200 300, 600, 1200, 2400, 4800, 9600, 19200 The speed in bits per second at which data is transferred on the DH-485 link.